Caravan Water Pump Keeps Running? What to Check Before Replacing It
Continuous running does not automatically mean a caravan water pump needs replacing. An empty water container, trapped air, an open drain valve or a leak can stop a pressure-controlled system reaching its shut-off pressure. Start by identifying when it runs and how it is controlled.
Before checking: switch the pump off if it is running continuously without water or a clear reason. Before opening a strainer or disconnecting pipework, isolate the pump supply, turn off the water heater, allow hot water to cool and release pressure through a tap. Follow the instructions for your system.
First, check when the pump runs
- It runs continuously with every tap closed: on a pressure-controlled system, it may be unable to build enough pressure, or the control may not be switching it off.
- It stops, then briefly starts again with the taps closed: this is closed-tap cycling. Look for pressure being lost through a leak or back through a valve.
- It pulses while a tap is only slightly open: some pressure-switched systems normally cycle at low flow. Rapid cycling with the tap fully open, or a new change in behaviour, needs checking.
A short delay after closing a tap can be normal on some installations. Whale describes run-on of up to 30 seconds for certain pressure-switch systems with a water heater or surge damper. That is not a universal allowance for every pump: use your own handbook and investigate a persistent change.
Check how your water pump is controlled
The pump type and the switching arrangement are separate things. A submersible pump can be used with more than one type of control.
- Onboard pressure pump: an automatic diaphragm pump, such as a Shurflo, normally has a pressure switch built into the pump assembly. Opening a tap lowers pressure and starts it.
- Submersible pump with pressure control: the pump sits in the water supply, while a separate pressure switch or electronic controller operates it. The switch may be behind the external inlet socket.
- Tap microswitch system: a switch operated by the tap calls for the pump to run. Pressure-switch adjustment advice does not apply to a system controlled only by tap microswitches.

Check the vehicle handbook, pump label and any controller label before following adjustment advice. If the system uses tap microswitches and the pump runs with every tap closed, the tap switches, wiring or control circuit may need checking. Leave electrical fault-finding to a competent technician.
1. Check the water supply and prime the system
Check the actual water level in the tank or external container. For a submersible pump, make sure the pump is properly covered by water. Inspect accessible supply hoses for kinks or crushing.
If the problem started after the container ran empty, after refilling or after winter drain-down, check the priming procedure in the handbook. Sputtering or air from the tap is a useful clue, but does not by itself prove an airlock.
For the Whale external pump assemblies covered by its pressure-switch guide, the refill sequence is to unplug the assembly, put the pump into the refilled container, then reconnect. Submerging it before reconnecting helps water enter the pump. Other systems have their own priming procedure.
Keep the water heater off until it has been correctly filled. Do not leave the pump running unattended in the hope that it will eventually prime.
2. Check taps, showers and drain valves
Make sure the kitchen tap, washroom tap, shower and any external shower are fully closed. On a pressure-controlled system, an open outlet can keep the pump running.
Then look for water leaving a drain beneath the vehicle. A drain valve left open after winterising can let the pump discharge water rather than pressurise the system.
If a Truma FrostControl valve is fitted, it can open automatically in cold conditions and drain the water heater. Check its operating instructions before refilling. Do not block the drain or force the valve to stay closed. Not every caravan or motorhome has this valve.
3. Look for water leaks and air entering the inlet
Inspect accessible pipe joints, tap connections, the pump, strainer and water heater connections for drips or dampness. A small leak on the pressurised side can make an automatic pump start again with all taps closed.
Also check the inlet side, between the water supply and the pump. A loose connection, cracked strainer bowl or damaged seal can let air in while the pump draws water. You may not see a puddle.
If water is leaking, switch the pump off and deal with the leak before continuing. Persistent closed-tap cycling without a visible leak can also involve a non-return valve or internal pump valves allowing pressure to fall. It needs further diagnosis before choosing a part.
4. Inspect the pump inlet strainer
If your pump has an inlet strainer, check its mesh for debris. A restriction here can reduce the water reaching the pump. A cracked bowl or poorly seated seal can cause an inlet air leak.
With the pump isolated and the system depressurised, clean and refit the strainer according to its instructions. Check that the seal is present, undamaged and seated correctly. Do not overtighten a plastic bowl or run the pump with the strainer removed.
The mesh strainer protects the pump against debris. It is a different component from a drinking-water carbon filter, so identify which part you are inspecting.

5. Check the pressure control and power supply
On a pressure-switched system, the pump must build enough pressure for the switch to stop it. A control fault or unsuitable setting can cause run-on, but so can the supply and plumbing problems above.
Check the battery and charging status using the normal vehicle controls. Whale notes that changes in supply voltage can affect some adjustable pressure-switch systems. If proper voltage checks at the pump are needed, have the supply and connections checked by a competent person.
Do not turn an adjustment screw until the pump happens to stop. Settings and procedures differ between pumps, inlet switches and electronic controllers. Use the exact model instructions; an electronic controller may require calibration rather than mechanical adjustment.

When does the water pump need replacing?
If the supply, priming, drain valves, leaks, strainer, electrical supply and controls have been checked, the pump itself may need attention. Worn or contaminated internal valves, a damaged diaphragm or a faulty pressure switch are possible faults on relevant pump designs.
Some models have service parts; others are replaced as an assembly. A pump that runs but does not move water is not enough evidence on its own to condemn it. Ask for the fault to be confirmed if the basic checks do not resolve it.
Before ordering a replacement water pump
Use the full model number and match the specification required by the vehicle. Check:
- Voltage and electrical requirements, including the specified fuse and wiring.
- Pressure and flow rate. A higher-pressure pump is not automatically an upgrade; stay within the limits of the heater and plumbing.
- Pump and control type: onboard diaphragm, submersible, tap microswitch, pressure switch or electronic controller.
- Connections and installation: hose or pipe size, thread or plug type, mounting position and available space.
A similar-looking pump, or one sold for the same make of caravan, may have a different specification. Compare the existing label with the vehicle requirements before ordering. Browse our caravan and motorhome water pumps and spares.
Need help identifying a pump or spare?
Send us a clear photo of the pump label, a wider photo showing its connections and any separate controller, plus the make, model and year of your caravan or motorhome. Tell us whether the pump runs continuously, restarts with the taps closed or pulses while a tap is open, and whether water flows normally.
Contact Thomas Touring for help identifying the part. A photo can help us identify equipment, but some faults need the system to be inspected.
Technical references
These checks draw on manufacturer guidance. Always use the instructions for the equipment fitted to your own vehicle.
- Pentair Shurflo pump troubleshooting guide (PDF)
- Swift Group water-system fault-finding guidance
- Whale: Adjusting Your Pressure Switch (manufacturer leaflet, PDF hosted by Propex)
- Whale Watermaster instructions (manufacturer manual, PDF hosted by RV World)
- Bailey Approach owner’s handbook: water-system and filter guidance (PDF)
- Truma FrostControl operating instructions (manufacturer manual, PDF hosted by HypeCamper)